Common problems and solutions of HRV fresh air system
Strike or unable to start
Check if the power socket is powered and restart the system
Clean the filter and pipe garbage (such as wasp nests, dust accumulation)
When the accessories of old models are discontinued, you can contact the manufacturer for upgrading
Reduced air volume
Dust accumulation in the filter increases the wind resistance and needs to be replaced periodically (primary/medium efficiency filter 6 months, high efficiency filter 6-12 months)
Check for pipe leakage or blockage of the air outlet, such as pipe deformation, insect nest residue, etc.
Abnormal noise
Improper installation of the filter or vibration of the body requires re-fixing the filter and the host
Avoid long-term high-power operation and adjust the wind speed according to needs
Check if the air outlet is damaged and repair or replace it in time
Air odor/secondary pollution
Long-term failure to replace the filter leads to accumulation of pollutants, and replacement prompts must be followed
Pipeline pollution (such as mold and dust) needs to be cleaned regularly
Usage and maintenance suggestions
Environmental adaptability
If the outdoor dust is too high (such as during construction), it is recommended to temporarily turn it off to prevent pollution backflow
When used with air conditioning/heating, the heat exchange function can save energy by 50% Above
Key points of regular maintenance
Filter management: prompt replacement through the intelligent monitoring system to avoid manual estimation errors
Pipeline inspection: comprehensive cleaning at least once a year, focusing on checking the return air duct leakage problem
Waterproof and moisture-proof: Check whether there is water accumulation inside the host in winter, and deal with mildew in time
Installation precautions
Preferentially choose the upper air supply duct layout, reduce crossing and bending to reduce wind loss
It is recommended to add rainproof wind caps in basements or humid areas to avoid rainwater backflow
Function and design analysis
Heat exchange principle
Recover energy through sensible heat (temperature exchange) and latent heat (humidity exchange) to maintain stable indoor temperature and humidity
Machine
Model selection reference
The common air volume for ordinary households is 150-350m³/h, which needs to be calculated comprehensively based on the room area and the number of people
The noise of silent models can be as low as 16 decibels, suitable for bedroom use
Difference from air conditioners
The new air fan focuses on air purification and ventilation, and cannot replace the cooling/heating function of air conditioners, but can work together to improve comfort